| A | Insulated Chimney |
| B | Storm Collar |
| C | Roof flashing |
| D | Roof support to retain chimney |
| E | Twin wall to single wall adaptor |
| F | Single wall flue pipe. Twin wall is also suitable |
| G | Wall support. Retains internal flue |
| H | Internal bends |
| I | Flue starter kit |
| J | Flue to adaptor |
| K | Debris trap for falling soot (with water drain point in the end cap) |
| L | Flue support stand |
Single wall chimney may be used inside a building however we would recommend twin-wall insulated chimney.
Good access for cleaning must be included in the chimney system.
The weight of the chimney should be supported by a stand and not the rear of the appliance.
These should be kept to a minmium. Where a bend is needed it should be of no more than 45deg.
We do not recommend a chimney cowl as this can slow the volume of flue gasses. We recommed a cap of the connecting T pipe to include a drain point. This drain will allow any excess rain which enters chimney to exit the chimney system.
There are several different methods to pass through a roof.